Compatibility table for outdoor units and Hydroset .
Cooling / heating capacity up to 3 kWt
Hydroset model outdoor unit type
recomended water temp.
The systems use standard Mitsubishi Electric outdoor units purchased from any supplier.
Hydroset UNI-1RC | + | MUZ-SF25VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-EF25VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH25VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH25VEHZ | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-2D30/33VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | SUZ-KA25VA | Mono | +500C…+530C |
Cooling / heating capacity up to 4 kWt
Hydroset model outdoor unit type
recomended water temp.
Using Hydroset as a mini-chiller gives significant advantages over monoblock systems:
*not need use glycol in the system. Hydroset can be placed in a heated room, and work directly with water in the system.
* the efficiency of the system is higher due to the lack of an additional heat transfer circuit.
*inverter control allows the use of a minimum water buffer tank.
*digital control and visualization of processes
Hydroset UNI-1RC | + | MUZ-SF35VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-EF35VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH35VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH35VEHZ | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-2D40VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | SUZ-KA35VA | Mono | +500C…+530C |
Hydroset UNI-1RC | + | PUHZ-ZRP35VKA | Mono | +500C…+530C |
Cooling / heating capacity up to 6 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-1RC | + | MUZ-SF50VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-EF50VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH50VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MUZ-FH50VEHZ | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-2D52/53VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | SUZ-KA50VA | Mono | +500C…+530C |
Hydroset UNI-1RC | + | PUHZ-ZRP50VKA | Mono | +500C…+530C |
Cooling / heating capacity up to 7 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-1RC | + | MUZ-GF60VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-3D54VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | SUZ-KA60VA | Mono | +500C…+530C |
Hydroset UNI-1RC | + | PUHZ-ZRP60VKA | Mono | +500C…+530C |
Cooling / heating capacity up to 9 kWt
Hydroset model outdoor unit type
recomended water temp.
The power of the systems indicated in the tables is indicative. The total capacity corresponds to the data for the corresponding outdoor unit in the catalog.
In accordance with the recommendations of Mitsubishi Electric in the outdoor unit, it is necessary to install a heaterin the drain pan that does not allow ice to form in the outdoor unit when working on heat.
Hydroset UNI-1RC | + | MUZ-GF71VE | Mono | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-3D68VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-4D71/72VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-4E83VAHZ | muLti | +500C…+600C |
Hydroset UNI-1RC | + | MXZ-4D80/83VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-5D100/102VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | MXZ-6D120/122VA | muLti | +470C…+500C |
Hydroset UNI-1RC | + | SUZ-KA71VA | Mono | +500C…+530C |
Hydroset UNI-1RC | + | PUHZ-ZRP71VHA | Mono | +500C…+530C |
Hydroset UNI-1RC | + | PUHZ-SHW80VHA | Mono | +500C…+600C |
Hydroset UNI-1RC | + | PUMY-P112V/YKM | muLti | +500C…+530C |
Hydroset UNI-1RC | + | PUMY-P125V/YKM | muLti | +500C…+530C |
Hydroset UNI-1RC | + | PUMY-P140V/YKM | muLti | +500C…+530C |
Hydroset UNI-1RC | + | PUMY-P200YKM | muLti | +500C…+530C |
Cooling / heating capacity up to 11 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-2RC | + | PUHZ-P100VHA | Mono | +500C…+530C |
Hydroset UNI-2RC | + | PUHZ-ZRP100V/YKA | Mono | +500C…+550C |
Hydroset UNI-2RC | + | PUHZ-SHW112V/YHA | Mono | +500C…+600C |
Hydroset UNI-2RC | + | PUMY-P112V/YKM | muLti* | +500C…+530C |
* full power of the outdoor unit can be obtained only with the use of an optional expansion valve
The heater control is a regular function of Hydroset. Does not require any additional monitoring devices. Just need to connect to the appropriate contacts.
The recommended temperature of the coolant depends only on the class of the outdoor unit. If you install it above the recommended value, at very low temperatures, you may stop by error of the outdoor unit.
Cooling / heating capacity up to 14 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-2RC | + | PUHZ-P125V/YHA | Mono | +500C…+530C |
Hydroset UNI-2RC | + | PUHZ-ZRP125V/YKA | Mono | +500C…+550C |
Hydroset UNI-2RC | + | PUMY-P125V/YKM | muLti* | +500C…+530C |
* full power of the outdoor unit can be obtained only with the use of an optional expansion valve
Cooling / heating capacity up to 16 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-2RC | + | PUHZ-P140V/YHA | Mono | +500C…+530C |
Hydroset UNI-2RC | + | PUHZ-ZRP140V/YKA | Mono | +500C…+550C |
Hydroset UNI-2RC | + | PUHZ-SHW140YHA | Mono | +500C…+600C |
Hydroset UNI-2RC | + | PUMY-P140V/YKM | muLti* | +500C…+530C |
* full power of the outdoor unit can be obtained only with the use of an optional expansion valve
The lower the desired temperature of the coolant, the higher the efficiency of the system, and the greater the resource of the main components and components.
windshield
windshield
Cooling / heating capacity up to 22 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-3RC | + | PUHZ-P200YKA | Mono | +500C…+530C |
Hydroset UNI-3RC | + | PUHZ-ZRP200YKA | Mono | +500C…+550C |
Hydroset UNI-3RC | + | PUHZ-SHW230YKA | Mono | +500C…+600C |
Hydroset UNI-3RC | + | PUMY-P200YKM | muLti* | +500C…+530C |
* full power of the outdoor unit can be obtained only with the use of an optional expansion valve
If it is not possible to install the outdoor unit in a place with natural wind protection, it is recommended to equip it with wind and snow protection.
This will improve its performance in high winds, and accelerate the passage of defrosting.
Cooling / heating capacity up to 27 kWt
Hydroset model outdoor unit type
recomended water temp.
Hydroset UNI-3RC | + | PUHZ-P250YKA | Mono | +500C…+530C |
Hydroset UNI-3RC | + | PUHZ-ZRP250YKA | Mono | +500C…+550C |